Bs 6622 iec 60502-2 pdf

This will be a layer of semiconducting xlpe which will be. Bs 6622, bs 6234, bs 7454 iec 605022, iec60840 construction conductors. Accessories for special applications, such as aerial cables, submarine or ship cables or hazardous situations explosive environments, fireresistant cables or. This second edition cancels and replaces the first edition published in 1997, its amendment 1 1998 and its corrigendum 1 1999 and constitutes a technical revision. European standards iec, bs, nf and vde specifications. They are designed to produce low levels of smoke and corrosive gases on exposure to fire compared to the cables specified in british standard bs6622. They are also suitable for direct burial installation in free. Suitable for laying indoors, in cable ducts, outdoors and laying underground for power stations and distribution networks.

For smaller sizes, a solid round conductor, class 1 as per iec 60228, bs en 60228 can also be supplied upon request. Part 2 annex b, has a calculation method for determining current capacities for voltages covered by this part. Bs 6622 description electric cable with copper conductors, semiconductive conductor screen, xlpe insulation, semiconductive insulation screen, copper tape metallic screen of each core, pvc bedding, galvanized steel wires armour swa and pvc outer sheath. Mv cables to iec 605022 up to 1830 36 kv and to bs 6622. British standard bs7835 specifies requirements for singlecore and threecore armoured cables with thermosetting insulation 3. Ukas medium voltage cables jeddahcabies company outer sheath jacket. The power cable as per our specification is according to iec 60502 and contractor is offering. International standard iec 605022 has been prepared by iec technical committee 20. Basec expands its international cable standards testing. Test requirements on accessories for cables with rated voltages from 6 kv um 7,2 kv up to 30 kv um 36 kv. The scope of this catalogue is to provide an in depth view of the technical information of the medium voltage cables up to 36 kv, with xlpe insulation to iec 605022 and bs 6622.

This group is complying with iec 60502 2 or bs 6622. Outdoor energy cables, mv underground power cables, iecbs mv, xlpe insulation, cws, awa, pvc 1c main content main menu this site uses cookies so that we can provide you with the best user experience. Xlpe power cable, which standard is better iec 60502 or bs 5467 xlpe power cable, which standard is better iec 60502 or bs 5467 sramesh mechanical op 11 aug 08 06. Cables for rated voltages from 6 kv um 7, 2 kv up to 30 kv um 36 kv. Medium voltage cables to iec 605022 up to 1830 36 kv and to bs 6622 up to 1933 36 kv. Medium voltage xlpe insulated cables to iec 605022, bs 6622, bs 7835. Pvc insulation material and thickness shall be as per iec 605021 and bs 6346.

Xlpe insulated cable of voltage rating up to 19003300v shall comply with iec 605021 or bs 5467. Suitable for power transmission, outdoors and direct burial. Mv cables to iec 605022 up to 1830 36 kv and to bs 6622 up to 1933 36 kv, which is covered in the catalogue, in addition to other products described in separate catalogues. Bs 6622 iec 60228 iec 60502 2 flame retardant to iec 603321 design. Also used in industries, commercial complexes with high energy requirements. Medium voltage cables to iec 60502caledonian medium. Low voltage power cables with xlpe insulation and pvc sheathing to iec 605021, bs 5476, and bs 7889 or medium voltage power cables to iec 605022 up to 1830 36 kv and to bs. These power cables are used for electricity supply in medium voltage installation system. All bsi british standards available online in electronic and print formats. While 100% of the cables are tested for routine tests prior to dispatch, however upon.

Thermosetting insulated, armoured cables of rated voltages of 6001 000 v and 1 9003 300 v for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Area bahra cables company has a total land area of about 500,000 sqm at disposal. The scope of this catalogue is to provide an in depth view of the technical information of the medium voltage cables up to 36 kv, with xlpe insulation to iec 60502 2 and bs 6622. In this instance, a cable manufacturer may describe its cable product to potential customers together with the equivalent british standards it has achieved, for example. Caledonian medium voltage cables are normally supplied with red pvc oversheaths complying with bs 6622 or iec 60502. Extruded semiconducting xlpe crosslinked polyethylene solidly bonded. Mv cables to iec 605022 up to 1830 36 kv and to bs 6622 up to 1933 36 kv. Power cables with extruded insulation and their accessories for rated voltages from 1 kv um 1,2 kv up to 30 kv um 36 kv part 2. Electric cable with copper conductor, semiconductive conductor screen, xlpe insulation, semiconductive insulation screen, copper tape metallic screen, pvc bedding, aluminium wires armour awa, pvc outer sheath.

Armoured cables with thermosetting insulation for rated voltages from 3. Xlpe insulated cable of voltage rating 66001v shall comply with iec 60502 2 or bs 6622. Part 1 does not contain any current capacity sizing, as this is intended to be covered by iec 60364. Lv power cables with pvc and xlpe insulation to iec 605021, bs 5476, bs 7889 and ul 1277. The 11kv cable is suitable for rated voltage 610kv according to iec 605022. Where this is the case, technical specifications refer to cables being manufactured generally to iec 605022. It should be noted that iec 605022 excludes cables for special conditions such as those manufactured for use in overhead lines, mining, nuclear power plants, marine and submarine applications. This group is complying with iec 605022 or bs 6622. Bs 6622 iec 60228 iec 605022 flame retardant to iec 603321 design. Bs7835 cable selection we supply a comprehensive range of medium voltage mv cables, including low smoke zero halogen lszh thermoplastic oversheathed cables manufactured in accordance with british standard bs 7835. Xlpe insulated cable of voltage rating up to 19003300v shall comply with iec 60502 1 or bs 5467.

Mv cables medium voltage wire manufacturers nuhas oman. Our cable armoring is in compliance with the requirements of iec 605022 and bs 6622. Iecbs mv, xlpe insulation, cws, awa, pvc 1c nexans. Electric cable with copper conductor, semiconductive conductor screen, xlpe insulation, semiconductive insulation screen, copper metallic screen on each core, pvc bedding, aluminium wires armour. Xlpe insulated cable of voltage rating 6600111 ooov shall comply with iec 605022 or bs 6622. Xlpe power cable, which standard is better iec 60502 or bs. This british standard sets out the specifications and required tests for single core and three core armoured.

Cables complying with bs 6622 and customers specification are available upon request. Electric cable with copper conductors, semiconductive conductor screen, xlpe insulation, semiconductive insulation screen, copper tape. Annex to declaration of accreditation scope of accreditation normative document. The cables can be single core, and three cores cable. Cables for rated voltages from 6 kv um 7,2 kv up to 30 kv um 36 kv. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed. Low voltage power cables with xlpe insulation and pvc sheathing to iec 60502 1, bs 5476, and bs 7889 or medium voltage power cables to iec 60502 2 up to 1830 36 kv and to bs.

Bs 6622 is a british standard that specifies requirements and test methods for the construction, dimensions and mechanical and electrical properties of armoured cables with thermosetting insulation for rated voltages from 3. Cables for rated voltages of 1 kv u m 1, 2 kv and 3 kv u m 3,6 kv. The cable is suitable for rated voltage 610kv according to iec 60502 2. Bahra cables company has a total land area of about 500,000. Insulated armoured cables to bs6622 stranded copper or aluminium conductors conductor. The single core cables are designed for distribution of electrical power with nominal voltage uou ranging from. Cables for rated voltages from 6 kv um 7,2 kv up to kv um 36 kv international electrotechnical commission rp ics 29. Bs6622 11kv medium voltage electric power cable with copper conductors, semiconductive conductor screen, xlpe insulation, semiconductive insulation screen, copper tape metallic screen, pvc bedding, galvanised steel wire armour swa and pvc outer sheath. Good day to all i am doing a project of adding a lv motor to the existing plant.

Pvc material shall be type a as per iec 605021 or ti1 as per bs en 50363. Low voltage four core insulated power cable tenaga. Bs6622 iec 60502 11kv galvanised steel wire armoured swa, xlpe insulated, pvc sheathed, 3 core cable used for electricity supply in medium voltage mv installation power supply plants. Medium voltage xlpe insulated cables to iec 60502 2, bs 6622, bs 7835. Packed in wooden drums or steelwooden drums or as your request.

Xlpe insulated cable of voltage rating 66001v shall comply with iec 605022 or bs 6622. Xlpe insulated cable of voltage rating 6600111 ooov shall comply with iec 60502 2 or bs 6622. The cable is suitable for rated voltage 610kv according to iec 605022. These cables are designed to have improved fire performance when installed in air.